Explosion-proof electric ball valve

Size :½” – 12″ (DN15 – DN300)
Pressure : Class 150、Class 300,PN10-PN40
Connections:
ASME B16.34 class 150、ASME B16.34 class 300
DIN PN16、PN25、PN40
JIS 10K、20K
Body: CF8,CF8M,CF3M,WCB
Seat :PTFE、PEEK
Electric Actuator: ON-OFF type、Regulation type
Control signal: 4-20 mADC、0-5 VDC、0-10 VDC
Power: 12 VDC,24 VAC,24 VDC,220 VAC,120 VAC,380 VAC 50/60 Hz
Explosion-proof: EXd II CT5, EXd II BT4







    Description

    Explosion-proof electric ball valve ON-OFF,4-20mA

    Our ATEX electric ball valve is designed to safely and effectively control the flow of flammable gases and vapors as well as dust in hazardous areas. Our reliable electric actuator ball valve offers precise automated control to minimize human error and increase productivity. Our electric actuated ball valve is designed to meet the safety requirements of ATEX by utilizing durable construction materials and corrosion resistant materials. The electric ball valve actuator provides precise flow control and leak-tight operation in a variety of demanding industrial applications.

    Explosion-proof electric ball valve

    The motorized ball valve operates as an automated system which enables easy connection to control systems for continuous system monitoring and distant control operation. The motorized ball valve serves multiple industries including chemical processing and oil and gas and petrochemicals because it ensures both operational safety and maximum efficiency. The ball valve with electric actuator or electronic ball valve design provides explosion-proof reliability for demanding applications.

     

    EX electric ball valve

    Electric ball valve Standard technical parameters Design:

    GB ASME DIN JIS
    Design GB/T12237/1989 ASME B16.34
    API608
    DIN 3357/1
    2EN12516-1
    ASME B16.34
    API608
    Pressure PN116-PN40 ASME B16.34 CLASS 150
    ASME B16.34 CLASS 300
    DIN3357/EN12516-1
    PN10-PN40
    JISB2001 10K
    JIS B2001 20K
    Face to face GB/T12221 ASME B16.10 DIN 3202 JIS B2002
    End Flange GB/T9113 JB/T79 ASME B16.5 DIN 2543-2545 JIS B2212
    JIS B2214
    Inspection Testing GB/T13927 API 598 DIN 3230/3 JIS B2003
    Fire safe API 607 API 607 4 th1993 API 607 4 th1993 API 607 4 th1993
    Ports Full port
    Body style Two piece
    Size ½” – 12″ (12mm – 300mm)
    Temper range -50°f to 650°f (-46°c to 343°c)
    Pressure ratings ASME class 150、ASME class 300.
    (PN10 to PN40 covered)
    End ASME B16.34 class 150、ASME B16.34 class 300
    DIN PN16、PN25、PN40
    JIS 10K、20K
    Body Stainless steel(CF8、CF8M、CF3M)、 carbon steel (WCB)
    Seat PTFE、PEEK
    Applications Process, tank farms, fueling, oil & gas

    Ball valve Design features:

    Built-in ISO 5211 Direct mounting pad easy automation
    frie safe design approved
    Anti-static devices for ball-stem-body
    Blow-out proof stem
    Pressure balance hole in ball slot
    TA-LUFT design approved
    Casting boss on body for draining

    Electric Actuator

    Output Torque 50Nm to 2000Nm
    Control: ON-OFF type、Regulation type
    Control signal: 4-20 mADC、0-5 VDC、0-10 VDC
    Power: 12 VDC,24 VAC,24 VDC,220 VAC,120 VAC,380 VAC 50/60 Hz
    Explosion-proof: EXd II CT5

    Electric ball valve application

    Electric ball valve application

    Electric ball valve JIS 10K Flanged

    NPS ΦD L ΦE ΦB ΦC T f N-Φh H H1 W M P ΦA1 ΦA2 B1 B2
    15 15 108 95 70 52 12 1 4-15 48 79 135 9 9 6 6 36 42
    20 20 117 100 75 58 14 1 4-15 53 84 135 9 9 6 6 36 42
    25 25 127 125 90 70 14 1 4-19 64 95 170 11 11 6 7 42 50
    32 32 140 135 100 80 16 2 4-19 71 103 170 11 11 6 7 42 50
    40 38 165 140 105 85 16 2 4-19 76 111 200 14 14 7 9 50 70
    50 50 178 155 120 100 16 2 4-19 85 120 200 14 14 7 9 50 70
    65 64 190 175 140 120 18 2 4-19 104 153 300 17 17 9 11 70 102
    80 76 203 185 150 130 18 2 8-19 114 163 300 17 17 9 11 70 102
    100 100 229 210 175 155 18 2 8-19 140 182 400 22 22 non 11 non 102
    125 125 356 250 210 185 20 2 8-23 183 260 800 27 27 14 non 125 non
    150 150 394 280 240 215 22 2 8-23 202 280 800 27 27 14 non 125 non
    200 200 457 330 290 265 22 2 12-23 253 non 800 27 27 14 non 125 non

    Electric ball valve JIS 20K Flanged

    NPS ΦD L ΦE ΦB ΦC T f N-Φh H H1 W M P ΦA1 ΦA2 B1 B2
    15 15 140 95 70 52 14 1 4-15 48 79 135 9 9 6 6 36 42
    20 20 152 100 75 58 16 1 4-15 53 84 135 9 9 6 6 36 42
    25 25 165 125 90 70 16 1 4-19 64 95 170 11 11 6 7 42 50
    32 32 178 135 100 80 18 2 4-19 71 103 170 11 11 6 7 42 50
    40 38 190 140 105 85 18 2 4-19 76 111 200 14 14 7 9 50 70
    50 50 216 155 120 100 18 2 8-19 85 120 200 14 14 7 9 50 70
    65 64 241 175 140 120 20 2 8-19 104 153 300 17 17 9 11 70 102
    80 76 283 200 160 135 22 2 8-23 114 163 300 17 17 9 11 70 102
    100 100 305 225 185 160 24 2 8-23 140 182 400 22 22 non 11 non 102
    125 125 381 270 225 195 26 2 8-25 183 260 800 27 27 14 non 125 non
    150 150 403 305 260 230 28 2 12-25 202 280 800 27 27 14 non 125 non
    200 200 502 350 305 275 30 2 12-25 253 non 800 27 27 14 non 125 non

    Electric actuated ball valve ANSI 150LB Flanged

    NPS ΦD L ΦE ΦB ΦC T f N-Φh H W M P ΦA1 ΦA2 B1 B2
    1/2″ 13 108 90 60.3 34.9 11.6 2 4-16 51 135 9 9 7 8 36 50
    3/4″ 19 117 100 69.9 42.9 13.2 2 4-16 55 135 9 9 7 8 36 50
    1″ 25 127 110 79.4 50.8 14.7 2 4-16 68 170 11 11 7 8 42 50
    1-1/4″ 32 140 115 88.9 63.5 16.3 2 4-16 74 170 11 11 7 8 42 50
    1-1/2″ 38 165 125 98.4 73 17.9 2 4-16 82 200 14 14 8 10 50 70
    2″ 51 178 150 120.7 92.1 19.5 2 4-19 92 200 14 14 8 10 50 70
    2-1/2″ 64 190 180 139.7 104.8 22.7 2 4-19 116 300 17 17 10 12 70 102
    3″ 76 203 190 152.4 127 24.3 2 4-19 129 300 17 17 10 12 70 102
    4″ 102 229 230 190.5 157.2 24.3 2 8-19 148 400 22 22 non 12 non 102
    5″ 127 356 255 215.9 185.7 24.3 2 8-22 184 800 27 27 14 18 125 140
    6″ 152 394 280 241.3 215.9 25.9 2 8-22 206 800 27 27 14 18 125 140
    8″ 203 457 345 298.5 269.9 29 2 8-22 254 800 27 27 18 22 140 165

    Electric actuated ball valve ANSI 300LB Flanged

    NPS ΦD L ΦE ΦB ΦC T f N-Φh H W M P ΦA1 ΦA2 B1 B2
    1/2″ 13 140 95 66.7 34.9 14.7 2 4-16 51 135 9 9 7 8 36 50
    3/4″ 19 152 115 82.6 42.9 16.3 2 4-19 55 135 9 9 7 8 36 50
    1″ 25 165 125 88.9 50.8 17.9 2 4-19 68 170 11 11 7 8 42 50
    1-1/4″ 32 178 135 98.4 63.5 19.5 2 4-19 74 170 11 11 7 8 42 50
    1-1/2″ 38 190 155 114.3 73 21.1 2 4-22 82 200 14 14 8 10 50 70
    2″ 51 216 165 127 92.1 22.7 2 8-19 92 200 14 14 8 10 50 70
    2-1/2″ 64 241 190 149.2 104.8 25.9 2 8-22 116 300 17 17 10 12 70 102
    3″ 76 283 210 168.3 127 29 2 8-22 129 300 17 17 10 12 70 102
    4″ 102 305 255 200 157.2 32.2 2 8-22 148 400 22 22 non 12 non 102
    5″ 127 381 280 235 185.7 35.4 2 8-22 184 800 27 27 14 18 125 140
    6″ 152 403 320 269.9 215.9 37 2 12-22 206 800 27 27 14 18 125 140
    8″ 203 502 380 330.2 269.9 41.7 2 12-25 254 800 27 27 18 22 140 165

    Electric actuated ball valve DIN PN16 Flanged

    DN L ΦE ΦB ΦC T f N-Φh H H1 W M P ΦA1 ΦA2 B1 B2
    15 130 95 65 45 16 2 4-14 48 79 135 9 9 6 6 36 42
    20 130 105 75 58 18 2 4-14 53 84 135 9 9 6 6 36 42
    25 140 115 85 68 18 2 4-14 64 95 170 11 11 6 7 42 50
    32 165 140 100 78 18 2 4-18 71 103 170 11 11 6 7 42 50
    40 165 150 110 88 18 2 4-18 76 111 200 14 14 7 9 50 70
    50 203 165 125 102 20 2 4-18 85 120 200 14 14 7 9 50 70
    65 222 185 145 122 18 2 (4)8-18 104 153 300 17 17 9 11 70 102
    80 241 200 160 138 20 2 8-18 114 163 300 17 17 9 11 70 102
    100 305 220 180 158 20 2 8-18 140 182 400 22 22 non 11 non 102
    125 356 250 210 188 22 2 8-18 183 260 800 27 27 14 non 125 non
    150 394 285 240 212 22 2 8-22 202 280 800 27 27 14 non 125 non
    200 457 340 295 268 24 2 12-22 253 non 800 27 27 14 non 125 non

    Electric actuated ball valve DIN PN25 Flanged

    DN L ΦE ΦB ΦC T f N-Φh H H1 W M P ΦA1 ΦA2 B1 B2
    15 130 95 65 45 16 2 4-14 48 79 135 9 9 6 6 36 42
    20 130 105 75 58 18 2 4-14 53 84 135 9 9 6 6 36 42
    25 140 115 85 68 18 2 4-14 64 95 170 11 11 6 7 42 50
    32 165 140 100 78 18 2 4-18 71 103 170 11 11 6 7 42 50
    40 165 150 110 88 18 2 4-18 76 111 200 14 14 7 9 50 70
    50 203 165 125 102 20 2 4-18 85 120 200 14 14 7 9 50 70
    65 241 185 145 122 22 2 8-18 104 153 300 17 17 9 11 70 102
    80 283 200 160 138 24 2 8-18 114 163 300 17 17 9 11 70 102
    100 305 235 190 162 24 2 8-22 140 182 400 22 22 non 11 non 102
    125 381 270 220 188 26 2 8-26 183 260 800 27 27 14 non 125 non
    150 403 300 250 212 28 2 8-26 202 280 800 27 27 14 non 125 non
    200 502 360 310 278 30 2 12-26 253 non 800 27 27 14 non 125 non

    Electric actuated ball valve DIN PN40 Flanged

    DN L ΦE ΦB ΦC T f D1 f1 N-Φh H H1 W M P ΦA1 ΦA2 B1 B2
    15 130 95 65 45 16 2 40 4 4-14 48 79 135 9 9 6 6 36 42
    20 130 105 75 58 18 2 51 4 4-14 53 84 135 9 9 6 6 36 42
    25 140 115 85 68 18 2 58 4 4-14 64 95 170 11 11 6 7 42 50
    32 165 140 100 78 18 2 66 4 4-18 71 103 170 11 11 6 7 42 50
    40 165 150 110 88 18 2 76 4 4-18 76 111 200 14 14 7 9 50 70
    50 203 165 125 102 20 2 88 4 4-18 85 120 200 14 14 7 9 50 70
    65 241 185 145 122 22 2 110 4 8-18 104 153 300 17 17 9 11 70 102
    80 283 200 160 138 24 2 121 4 8-18 114 163 300 17 17 9 11 70 102
    100 305 235 190 162 24 2 150 4.5 8-22 140 182 400 22 22 non 11 non 102
    125 381 270 220 188 26 2 176 4.5 8-26 183 260 500 27 27 14 non 125 non
    150 403 300 250 218 28 2 204 4.5 8-26 202 280 800 27 27 14 non 125 non
    200 502 375 320 285 34 2 260 4.5 12-30 253 non 1100 27 27 14 non 125 non

     







      Electric ball valve FAQ

      What is an explosion-proof ATEX electric ball valve?

      The ATEX electric ball valve operates in hazardous environments to control flow through automated operation in areas with flammable gases and vapors and dust particles. The valve operates safely in explosive environments because it holds ATEX certification. The electric actuator of this valve provides both precise and automated control of flow.

      POQ atex electric actuator

      What does ATEX certification mean for these electric valves?

      ATEX certification verifies that the valve fulfills all European safety requirements for equipment operating in explosive environments. The valve design and components under ATEX certification work to prevent ignition while delivering dependable operation in dangerous environments.

      What industries use explosion-proof ATEX electric ball valves?

      The valves serve multiple industries which include chemical processing and oil and gas and petrochemicals and mining and power generation. These valves operate in safety-critical environments that handle combustible materials because they need to maintain both safety and precise operation.







        Electric ball valve pdf

        VALVE PDF